• 5072PR, 5073PR, 5077PR 手动控制超声脉冲发生器接收器

    5072PR, 5073PR, 5077PR 手动控制超声脉冲发生器接收器

  • 2023-07-05 09:56 67
  • 产品价格:面议
  • 发货地址:广东省深圳市包装说明:不限
  • 产品数量:不限产品规格:不限
  • 信息编号:83680347公司编号:4264590
  • 李登彪 销售
    +8618675597965 (联系我请说明是在阿德采购网看到的信息)
  • 进入店铺 在线咨询 QQ咨询
  • 信息举报
    产品描述

    5072PR, 5073PR, 5077PR  5072PR手动控制超声脉冲发生器接收器既可用于常规应用,又可用于高频应用。用于一般检测的理想配置是35 MHz(-3 dB)带宽和尖脉冲发生器。 优化的宽带激励会产生极佳的时域恢复效果,特别是在15~30 MHz的情况下。5072PR手动控制超声脉冲发生器接收器既可用于常规应用,又可用于高频应用。用于一般检测的理想配置是35 MHz(-3 dB)带宽和尖脉冲发生器。 优化的宽带激励会产生极佳的时域恢复效果,特别是在15~30 MHz的情况下。

    5072PR, 5073PR, 5077PR

    The 5072PR, 5037PR, and 5077PR manually controlled ultrasonic pulser-receivers are for both conventional and high frequency applications

    These affordable and reliable manually controlled pulser-receivers provide the perfect building blocks for both conventional and high frequency applications. Each instrument is designed for superior low noise receiver response and high performance pulser control.
    When used with an appropriate transducer and analog or digital oscilloscope, Panametrics pulser-receivers provide the perfect starting point for ultrasonic flaw detection, thickness gaging, materials characterization, and transducer characterization.


    Features & Benefits

    • Three models provide optimization for both conventional and high frequency applications
    • Broadband Spike (5072 and 5073) or Tunable Square Wave (5077) transducer excitation models available
    • Front panel controls permit quick and easy setup of parameters for optimizing signal response
    • Each model delivers a wide dynamic range with 1 dB sensitivity adjustments made through a front panel lever switch
    • Low noise receiver amplification and pulser optimization ensure superior signal-to-noise characteristics
    • Superior isolation of receiver from pulser main bang when operating in thru-transmission mode
    • +/-1 volt RF output into 50 ohm load
    • Small, lightweight packaging

    Three Models To Fit Your Testing Needs

    Model 5072PR: 35 MHz (-3 dB) ultrasonic bandwidth and spike pulser is ideal for general testing. The impulse pulser provides optimal broadband excitation resulting in superior time domain recovery especially at higher frequencies (between 15-30 MHz).
    Model 5073PR: 75 MHz (-3 dB) ultrasonic bandwidth with fast rise time spike pulser extends performance for work with 50 MHz transducers in applications that challenge limits in axial and near surface resolution.
    Model 5077PR: 35 MHz (-3 dB) ultrasonic bandwidth and square wave pulser-receiver is ideal for maximizing response in scattering materials. The square wave pulser is particularly advantageous when testing with transducers of 10 MHz or lower, as adjustable pulse width optimizes pulse energy, resulting in superior signal-to-noise characteristic.

    Ultrasonic Pulser-Receivers

    Pulser-receivers employed with ultrasonic transducers and an analog or digital oscilloscope are the prime building blocks of any ultrasonic test system.
    The pulser section produces an electrical pulse to excite a transducer that converts the electrical input to mechanical energy, creating an ultrasonic wave. In pulse-echo applications, ultrasound travels through the test material until it is reflected from an interface back to the transducer. In thru- transmission applications, the ultrasound travels through the material to a second transducer acting as a receiver.
    In either case, the transducer reconverts the mechanical pulse into an electrical signal that is then amplified and conditioned by the receiver section. The resulting RF is then made available for further analysis. Since the customer chooses the waveform display and/or digitization methodology, infinite flexibility in measurement range and method may be pursued.

    Square Vs. Spike Excitation 


    Spike excitation pulsers optimize broadband response and near surface resolution.
    For applications involving the testing of thin materials with high frequency transducers where fast recovery time and broadband transducer response are important to insuring adequate time and depth resolution, Models 5072PR and 5073PR employ a spike excitation technique that produces an abrupt voltage transition followed by a recovery to the baseline. The ultra-fast rise times directly translate to broad spectral excitation resulting in wideband transducer response. It is possible to optimize transducer response by selecting pulse energy and damping values, which adjust pulse rise time, width, and voltage. In general, lower energy values and damping resistance will produce the sharpest rise times for the most efficient excitation of high frequency transducers. In fact, the 5073PR pulser electronics can achieve rise times of less than 2 ns, enabling the use of up to 50 MHz broadband transducers.
    Square wave pulsers dramatically increase sensitivity while maintaining broadband performance by tuning pulse width to the resonant frequency of the transducer.

    Square wave excitation is especially useful in applications involving the testing of thick or highly attenuating materials with low frequency transducers, typically improving both penetration capability and signal-to-noise ratio. The Model 5077PR provides square wave excitation with a fast pulse rise and fall time. The pulse voltage and pulse width are adjusted directly to provide precise control over pulse shape. By tuning the period (pulse width) of the square wave to half that of the transducer center frequency, pulse energy to the transducer at its natural resonant frequency is increased. This can result in an increase in signal amplitude as great as 12 dB or more as compared with spike pulsers using the same voltage setting. The effect is especially pronounced with transducers of 5 MHz and lower frequency.

    Specifications*

    PULSER 5072PR 5073PR 5077PR Pulse Type (main bang):Negative Negative Impulse Negative Square Wave Rise Time (10% to 90%):Typically 5 ns, 10 ns max Typically <2 ns Typically <10 ns, 20 ns max (rise and fall time) Available Pulse Voltage: (no load) -360 V -180 V Select -400 V, -300 V, -200 V, -100 V Available Pulse Energy:13, 26, 52, or 104 µjoules 2, 4, 8, or 16 µjoules N/A Damping:Select 15, 17, 20, 25, 36, 50, 100, or 500 ohms 12, 14, 17, 20, 25, 33, 50, or 100 ohms N/A Pulse Width:N/A N/A 10 preset fixed widths: 15-20,10, 7.5, 5.0-6.0, 3.5-4.0, 2-2.25, 1.0, 0.5, 0.25, 0.1 MHz. Variable +/-25% fine vernier tuning for each width. Mode: Pulse Echo or Thru-Transmission  Isolation (53 dB min):Typically 62 dB at 10 MHz Typically 62 dB at 50 MHz Typically 62 dB at 10 MHz Pulse Repetition Rate: (Internal)100, 200, 500, 1000, 2000, or 5000 Hz 200, 500, 1000, 2000, 5000, 10000, or 20000 Hz 100, 200, 500, 1000, 2000, 5000 Hz, except that maximum PRF is limited to: 2000 Hz FOR 0.5 MHz tranducers, 1000 MHz for 0.25 MHz transducers, and 50 Hz for 0.1 MHz transducers. Pulse Repetition Rate:0-6 kHz (External) 0-10 kHz 0-5 kHz (observe limitations of PRF versus pulse width) Synch Output Pulse:3 V into 50 ohms   External Trigger Input: (in series with 10 Kohms)2.4 V into 1000 PF 200 ns minimum pulse width 2.4 V into 1000 PF 200 ns minimum pulse width 2.4 V into 1000 PF 50 ns minimum pulse width  RECEIVER5072PR 5073PR 5077PR Maximum Bandwidth: (-3 dB, RL=50 ohms)1 kHz - 35 MHz 1 kHz - 75 MHz 1 kHz - 35 MHz Voltage Gain:0-59, 1 dB steps (RL=50 ohms) 0-39, 1 dB steps (RL=50 ohms) 0-59, 1 dB steps (RL=50 ohms) Phase: inverting or non-inverting (internal switch)  Attenuator Range:0-59, 1 dB steps (RL=50 ohms) 0-49, 1 dB steps (RL=50 ohms) 0-49, 1 dB steps (RL=50 ohms) High Pass Filter:1 kHz (out) or 1 MHz 1 kHz (out) or 5 MHz 1 kHz (out) or 1 MHz Low Pass Filter:35 MHz (out) or 10 MHz 75 MHz (out) or 20 MHz 35 MHz (out) or 10 MHz Noise:70 µV pk-pk typical, referred to input, BW=35 MHz 200 µV pk-pk typical, referred to input, BW=75 MHz 70 µV pk-pk typical, referred to input, BW=35 MHz Max Signal Output: +/-1V pk., terminated in 50 ohms  Input Resistance: (Thru-Transmission)500 ohms linear range 100 ohms > linear range 100 ohms linear range 50 ohms at levels > linear range 500 ohms Output Impedance:50 ohms 50 ohms 50 ohms Maximum Input Power:400 mW 400 mW 500 mW  UNIT 5072PR,5073PR,5077PR Input/Output:External Trigger In, Sync Out, RF Out, T/R and R: All BNC female connectors Power Main Requirements:100/120/220/240 VAC, 50/60 Hz Operating Temperature:0-50°C Size and Weight:7" W x 3.5" H x 9.1" D (178 mm x 89 mm x 232 mm); 5 lbs (2.3 kg)

     

    ORDERING INFORMATION: Each model is shipped with a power cord and operator manual. Transducers and cables are sold separately.
    Our sales department is available to discuss your application in detail and to assist with transducer selection.

    *All specifications are subject to change without notice.



    深圳华清仪器仪表有限公司成立于二OO六年八月,注
    
    册资金伍拾万元人民币,是一家主要从事仪器仪表开发、研制
    
    、销售服务于一体的多元化的高科技企业,熟悉国内外上千家
    
    仪研所及制造厂商的上万个品种的测量仪器及仪表。并且与国
    
    外内著名仪表生产厂商有着广泛的良好的合作基础。在同行领域中,我公司以科学管理的手段,优
    
    良的品牌、优质的产品以及优秀的售后服务倍受广大客户的青
    
    睐。
    
            公司主要销售的仪器有:示波器、信号源、电源、电子负
    
    载、频谱分析仪、波形记录仪、电能质量分析仪、功率分析仪
    
    、兆欧表、钳形表、红外热像仪、红外测温仪、超声波探伤仪
    
    、超声波测厚仪、涂层测厚仪、电子天平、声级计、测振仪、
    
    转速表、频闪仪、漏点仪、测温仪、烟气分析仪,气体检测仪
    
    风速仪、温湿度仪、粗糙度仪、硬度计、照度计,推拉力计、
    
    扭力计等测试仪器。尤其是示波器、频谱仪、超声波探伤仪、
    
    硬度计、推拉力计等电子测试仪器和无损检测仪器在行业的
    
    应用上我公司有丰富的经验!销售辐射全国,连同国内近二
    
    十个城市,建立了四十家联营及分销合作商。
    
          公司注重“以人为本、团结合作、追求卓越、”的企业
    
    文化秉承质量、诚信、用户至上、价格合理”的
    
    宗旨,建立一切以客户的需求为工作目标的经营理念。
    
           我们真诚欢迎国内外新老客户前来洽谈业务,交流技术,
    
    增进友谊,竭诚为您服! ! !

    欢迎来到深圳华清仪器仪表有限公司网站,我公司位于经济发达,交通发达,人口密集的中国经济中心城市—深圳。 具体地址是广东深圳公司街道地址,负责人是张运华。
    主要经营超声波探伤仪、数字示波器、超声波测厚仪、电子测量仪器。
    单位注册资金:人民币 10 万元以下。
    本公司在机械产品这一领域倾注了无限的热忱和激情,公司一直以客户为中心、为客户创造价值的理念、以品质、服务来赢得市场,衷心希望能与社会各界合作,共创成功,共创辉煌,携手共创美好明天!

    本页链接:http://www.cg160.cn/vgy-83680347.html
    以上信息由企业自行发布,该企业负责信息内容的完整性、真实性、准确性和合法性。阿德采购网对此不承担任何责任。 马上查看收录情况: 百度 360搜索 搜狗
深圳华清仪器仪表有限公司成立于二OO六年八月,注 册资金伍拾万元人民币,是一家主要从事仪器仪表开发、研制 、销售服务于一体的多元化的高科技企业,熟悉国内外上千家 仪研所及制造厂商的上万个品种的测量仪器及仪表。并且与国 外内著名仪表生产厂商有着广泛的良好的合作基础。在同行领域中,我公司以科学管..
相关分类
附近产地